Poor Surface Finish?

CauseSolution
Not enough coolantAdd coolant or increase pressure
Chip load per tooth too highDecrease feedrate
RPM too highDecrease RPM
ChippingSee “Chipping” causes
Poor floor finishAdd corner radius to tool